EX01: recorded results¶
Product version: 0.1.0. Recorded revision: f13a8285881ebb7030358487b142392a3775ffb0.
These observations were verified with the development runtime and its available resources. They do not qualify a non-source installation or validate a real mission. Numerical display values are rounded to six significant figures.
The actual sizing trace and final required/realized array areas describe the same coupled study. The engineering assessment is complete with warnings; this is a concept baseline, not flight qualification.
baseline¶
Run lifecycle: completed. Input snapshot: 42a4b195405d9435e0705addaff9502c6eee56df15ce83f661129ea93a19fd38.
Engineering evaluation: complete. A complete evaluation can retain mandatory warnings; it is not flight qualification.
| Quantity | Observed value | Unit |
|---|---|---|
| Nominal dry mass | 159.751 | kg |
| Required solar array area | 2.92045 | m² |
| Realized solar array area | 3 | m² |
| Minimum state of energy | 185.15 | Wh |
| Peak heater electrical power | 442.441 | W |
| Radiator area | 0 | m² |
| Loaded propellant | 20.4555 | kg |
| Total delta-v | 255 | m/s |
| Communications hardware mass | 4.85 | kg |
| Battery capacity | 900 | Wh |
| Reported cost estimate (base) | 8.3139e+06 | USD (2025) |
Result states¶
| Result | Availability | Execution | Assessment |
|---|---|---|---|
result.adcs |
succeeded | succeeded | not_assessed |
result.communications |
succeeded | succeeded | pass |
result.convergence |
succeeded | succeeded | not_assessed |
result.cost |
succeeded | succeeded | not_assessed |
result.environment |
succeeded | succeeded | not_assessed |
result.face-exposure |
succeeded | succeeded | not_assessed |
result.geometry |
succeeded | succeeded | warn |
result.geometry-environment-loading |
succeeded | succeeded | not_assessed |
result.launch |
succeeded | succeeded | warn |
result.lifetime |
succeeded | succeeded | warn |
result.mass |
succeeded | succeeded | not_assessed |
result.operations |
succeeded | succeeded | not_assessed |
result.placement |
succeeded | succeeded | warn |
result.power |
succeeded | succeeded | warn |
result.project-resolution |
succeeded | succeeded | not_assessed |
result.propulsion |
succeeded | succeeded | warn |
result.report-generation |
succeeded | succeeded | not_assessed |
result.spacecraft-mass-properties |
succeeded | succeeded | not_assessed |
result.system-execution |
succeeded | succeeded | not_assessed |
result.thermal |
succeeded | succeeded | warn |
These states describe different questions. A completed run can include partial calculations, warnings or failed engineering assessments.
Recorded diagnostics¶
| Result | Severity / code | Message |
|---|---|---|
result.geometry |
warning: execution.fallback-selected |
Geometry export used declared fallback fallback.freecad-command-adapter. |
result.power |
info: eps.heater.sustained-cold-bound |
EPS applies the modeled sustained cold-case heater demand throughout each affected mode, including sunlight and eclipse. This is a conservative energy bound, not installed capacity or a predicted thermostat duty cycle. |
Indexed evidence¶
Use the run manifest and artifact index to locate these registered records; the recorded hashes bind the observations to their contents.
| Artifact | SHA-256 |
|---|---|
artifact.convergence-trace |
76908955624b4dbbd8ff913494468b9f5286f1afbae8a0b803893b4ed53727e7 |