Skip to content

Engineering and result glossary

Use this glossary when a result label or guide introduces an unfamiliar term. Field spellings and allowed values remain in the contract reference.

Run and result terms

Term Meaning in Sindri Where to use it
Run bundle The recorded inputs, indexed results, artifacts and execution history of a study Find and share results
Manifest The entry record that identifies the run and points to its indexes Start here when opening a bundle
Artifact A registered file, such as a report, diagnostic or geometry export Follow its index entry and recorded integrity information
Resolved snapshot The exact study inputs after references, resources and defaults have been resolved Establish what was actually calculated
Lifecycle The state of the whole run: running, completed, failed, incomplete or cancelled Choose the next action in run control
Result availability Whether a result is present and usable in full or in part, failed, skipped or absent Check before reading its payload
Execution status Whether an individual calculation succeeded, partially completed, failed or was skipped Distinguish calculation problems from design constraints
Engineering assessment A result's pass, warn, fail or not-assessed judgment against its represented checks Review alongside quantities and issues
Applicability Whether the model, hardware and assumptions fit the case being evaluated Read before extending a result to another mission
Authority The evidence and provenance supporting an input, model or catalog property Evaluate estimate confidence
Convergence Satisfaction of the numerical iteration's stopping rule Review separately from engineering feasibility
Feasibility Whether the design satisfies its applicable engineering requirements Requires the relevant assessments and supporting evidence

See interpret a result for a worked reading sequence. A not_assessed result has no acceptance judgment.

Physical quantities and conventions

Term Meaning Reading check
EPS Electrical power system: generation, conditioning and storage Power method
BOL / EOL Beginning / end of life Compare capacity and demand at the same lifetime point
State of energy Stored battery energy, expressed in Wh Distinguish it from installed capacity and an energy margin
State of charge Stored charge fraction or percentage Check the model's definition before equating it to energy fraction
Depth of discharge Fraction of capacity drawn down Review the battery's allowed range and lifetime assumptions
Dry / wet mass Mass excluding / including the represented propellant load Mass cases and margin rules
CG / inertia Center of gravity / resistance to angular acceleration Preserve configuration, reference point and axes
Topology The selected structural layout used to arrange the spacecraft A fixed choice is distinct from a search across candidates
Scenario / state The operating case / physical configuration to which a result applies Avoid mixing hot/cold cases or stowed/deployed configurations
Margin Remaining capability relative to a demand or limit, using the stated convention Read its sign, units and denominator; definitions vary by check

Field suffixes commonly specify units: _w for W, _wh for Wh, _s for s, _kg for kg, _m2 for m² and _deg for degrees. A fraction uses a 0–1 scale unless its contract says otherwise. Temperatures in radiation equations use K; a displayed temperature in °C must be converted before using it in those equations.