Skip to content

EX05: recorded results

Product version: 0.1.0. Recorded revision: f13a8285881ebb7030358487b142392a3775ffb0.

These observations were verified with the development runtime and its available resources. They do not qualify a non-source installation or validate a real mission. Numerical display values are rounded to six significant figures.

Successful execution and failed launch assessment beside the stowed and available widths.

Open figure at full size

All selected calculations finish, but the stowed spacecraft exceeds the available launch width. EX13 changes only that width from 0.6 m to 1.8 m; placement completeness alone does not establish launch accommodation.

baseline

Run lifecycle: completed. Input snapshot: 80b05eadf84d7b9aa94a7cfc78c4c1000501dbcedbceacd09583b99da51dd93b.

Engineering evaluation: ineligible. A complete evaluation can retain mandatory warnings; it is not flight qualification.

Quantity Observed value Unit
Stowed width 0.84 m
Available launch width 0.6 m

Result states

Result Availability Execution Assessment
result.adcs succeeded succeeded not_assessed
result.communications succeeded succeeded pass
result.convergence succeeded succeeded not_assessed
result.cost succeeded succeeded not_assessed
result.environment succeeded succeeded not_assessed
result.face-exposure succeeded succeeded not_assessed
result.geometry succeeded succeeded warn
result.geometry-environment-loading succeeded succeeded not_assessed
result.launch succeeded succeeded fail
result.lifetime succeeded succeeded warn
result.mass succeeded succeeded not_assessed
result.operations succeeded succeeded not_assessed
result.placement succeeded succeeded warn
result.power succeeded succeeded warn
result.project-resolution succeeded succeeded not_assessed
result.propulsion succeeded succeeded warn
result.report-generation succeeded succeeded not_assessed
result.spacecraft-mass-properties succeeded succeeded not_assessed
result.system-execution succeeded succeeded not_assessed
result.thermal succeeded succeeded warn

These states describe different questions. A completed run can include partial calculations, warnings or failed engineering assessments.

Recorded diagnostics

Result Severity / code Message
result.geometry warning: execution.fallback-selected Geometry export used declared fallback fallback.freecad-command-adapter.
result.power info: eps.heater.sustained-cold-bound EPS applies the modeled sustained cold-case heater demand throughout each affected mode, including sunlight and eclipse. This is a conservative energy bound, not installed capacity or a predicted thermostat duty cycle.

Indexed evidence

Use the run manifest and artifact index to locate these registered records; the recorded hashes bind the observations to their contents.

Artifact SHA-256
artifact.convergence-trace e19f88521501fb2f7492965b74413e2b6685187f5894eae5af8bdee5c4095140

Supported interfaces.