Power and EPS results¶
Inspect generation, load, storage, degradation, margins and applicability together.
Contract version: 1.0.0. Download the full JSON schema.
Use the tables for exact field names, types and constraints. Wide tables scroll horizontally. How to read defaults, units and result states.
For interpretation and examples, read the engineering method.
Fields¶
Read the outcome¶
Start with the represented checks and any rejected hardware candidates.
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
assessment_status |
Assessment Status | Yes | Not specified | — |
applicability |
Model Applicability Assessment | Yes | Not specified | — |
issues |
array of Issue Record | No | [] |
— |
candidate_rejections |
array of Eps Candidate Rejection | No | [] |
— |
margins |
array of Eps Controlling Margin | Yes | Not specified | minItems: 1 |
Follow energy through the cycle¶
Connect loads and generation to each segment and the cycle-level storage requirement.
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
mode_loads |
array of Eps Mode Load Result | Yes | Not specified | minItems: 1 |
generation_cases |
array of Eps Generation Ledger Result | Yes | Not specified | minItems: 1 |
segments |
array of Eps Segment Energy Result | Yes | Not specified | minItems: 1maxItems: 64 |
energy_sizing |
Eps Energy Sizing Result | Yes | Not specified | — |
minimum_state_of_energy_wh |
number | Yes | Not specified | minimum: 0.0Minimum reported stored energy in watt-hours. Assess it with the relevant capacity, reserve and operating assumptions. |
Inspect the hardware and lifetime basis¶
Compare required/realized area and BOL/EOL hardware capability.
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
architecture |
Resolved Eps Architecture or null | No | null |
— |
required_solar_array_area_m2 |
number | Yes | Not specified | minimum: 0.0Calculated required array area in square metres under the stated assumptions. |
realized_solar_array_area_m2 |
number | Yes | Not specified | minimum: 0.0Area actually realized by the design, in square metres; compare it with the required area. |
panel_degradation |
Panel Degradation Result | Yes | Not specified | — |
battery_degradation |
Battery Degradation Result | Yes | Not specified | — |
Identity and other fields¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
method_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
mission_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
payload_kind |
string | No | "power" |
const: "power" |
payload_version |
string | No | "2.0.0" |
const: "2.0.0" |
phase |
string | Yes | Not specified | enum: ["pre", "post", "post_thermal"] |
spacecraft_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
Nested definitions¶
Open a definition below, or follow a type link in a field table. Direct links open the relevant section automatically.
Array Mass Basis
Array Mass Basis¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
active_area_m2 |
number | Yes | Not specified | minimum: 0.0 |
basis_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
component_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
electrical_section_area_m2 |
number or null | No | null |
anyOf branch 1: exclusiveMinimum: 0.0 |
gross_area_m2 |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
included_hardware |
array of string | Yes | Not specified | minItems: 1items: enum: ["substrate", "photovoltaics", "panel_wiring", "mounts", "mechanisms", "yoke"] |
method |
string | Yes | Not specified | enum: ["catalog_assembly", "catalog_areal", "provisional"] |
packing_factor |
number | Yes | Not specified | maximum: 1.0exclusiveMinimum: 0.0 |
panel_mass_kg |
number | Yes | Not specified | minimum: 0.0 |
physical_panel_ids |
array of string | No | [] |
items: minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
reference_packing_factor |
number | No | 1.0 |
maximum: 1.0exclusiveMinimum: 0.0 |
section_count |
integer | Yes | Not specified | minimum: 1 |
source_ids |
array of string | Yes | Not specified | minItems: 1items: minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
Battery Degradation Result
Battery Degradation Result¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
combined_retention |
number | Yes | Not specified | maximum: 1.0exclusiveMinimum: 0.0 |
equivalent_full_cycles |
number | Yes | Not specified | minimum: 0.0 |
technology |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
terms |
array of Eps Degradation Factor Term | Yes | Not specified | minItems: 1 |
uncertainty_case |
Eps Uncertainty Case | Yes | Not specified | — |
Eps Candidate Rejection
Eps Candidate Rejection¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
component_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
reason_codes |
array of string | Yes | Not specified | minItems: 1items: minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
role_id |
string | Yes | Not specified | enum: ["array", "battery", "pcdu"] |
Eps Controlling Margin
Eps Controlling Margin¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
assessment_status |
Assessment Status | Yes | Not specified | — |
controlling_component_id |
string or null | No | null |
anyOf branch 1: minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
controlling_segment_id |
string or null | No | null |
anyOf branch 1: minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
margin |
number | Yes | Not specified | — |
metric_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
unit |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
Eps Degradation Factor Term
Eps Degradation Factor Term¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
defaulted |
boolean | No | false |
— |
driver |
string | Yes | Not specified | enum: ["time", "radiation", "calendar", "throughput", "depth_of_discharge", "temperature"] |
factor |
number | Yes | Not specified | maximum: 1.0exclusiveMinimum: 0.0 |
factor_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
source_identity |
string | Yes | Not specified | minLength: 1maxLength: 512 |
Eps Energy Sizing Result
Eps Energy Sizing Result¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
assessment_status |
Assessment Status | Yes | Not specified | — |
controlling_segment_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
net_cycle_energy_wh |
number | Yes | Not specified | — |
recharge_margin_wh |
number | Yes | Not specified | — |
required_usable_energy_wh |
number | Yes | Not specified | minimum: 0.0 |
Eps Generation Ledger Result
Eps Generation Ledger Result¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
array_conversion_efficiency |
number | Yes | Not specified | maximum: 1.0exclusiveMinimum: 0.0 |
array_wiring_efficiency |
number | Yes | Not specified | maximum: 1.0exclusiveMinimum: 0.0 |
bol_power_density_w_per_m2 |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
delivered_power_density_w_per_m2 |
number | Yes | Not specified | minimum: 0.0 |
incidence_factor |
number | Yes | Not specified | minimum: 0.0maximum: 1.0 |
irradiance_factor |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
mode_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
panel_retention |
number | Yes | Not specified | maximum: 1.0exclusiveMinimum: 0.0 |
source_identity |
string | Yes | Not specified | minLength: 1maxLength: 512 |
sun_access_factor |
number | Yes | Not specified | minimum: 0.0maximum: 1.0 |
Eps Load Ledger Term
Eps Load Ledger Term¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
bus_load_w |
number | Yes | Not specified | minimum: 0.0 |
component_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
dissipated_fraction_override |
number or null | No | null |
anyOf branch 1: minimum: 0.0maximum: 1.0 |
load_regulator_efficiency |
number | Yes | Not specified | maximum: 1.0exclusiveMinimum: 0.0 |
load_wiring_efficiency |
number | Yes | Not specified | maximum: 1.0exclusiveMinimum: 0.0 |
reserve_factor |
number | No | 1.0 |
minimum: 1.0 |
source_identity |
string | Yes | Not specified | minLength: 1maxLength: 512 |
source_power_w |
number | Yes | Not specified | minimum: 0.0 |
state_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
subsystem_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
term_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
Eps Mode Load Result
Eps Mode Load Result¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
bus_load_w |
number | Yes | Not specified | minimum: 0.0 |
conversion_loss_w |
number | Yes | Not specified | minimum: 0.0 |
mode_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
source_load_w |
number | Yes | Not specified | minimum: 0.0 |
terms |
array of Eps Load Ledger Term | Yes | Not specified | — |
Eps Segment Energy Result
Eps Segment Energy Result¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
available_generation_w |
number | Yes | Not specified | minimum: 0.0 |
battery_bus_power_w |
number | Yes | Not specified | — |
battery_charge_efficiency |
number | Yes | Not specified | maximum: 1.0exclusiveMinimum: 0.0 |
battery_discharge_efficiency |
number | Yes | Not specified | maximum: 1.0exclusiveMinimum: 0.0 |
battery_energy_delta_wh |
number | Yes | Not specified | — |
battery_terminal_power_w |
number | Yes | Not specified | — |
bus_load_w |
number | Yes | Not specified | minimum: 0.0 |
curtailed_generation_w |
number | Yes | Not specified | minimum: 0.0 |
delivered_generation_w |
number | Yes | Not specified | minimum: 0.0 |
duration_s |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
environment_state |
Eps Environment State | Yes | Not specified | — |
mode_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
segment_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
state_of_energy_end_wh |
number | Yes | Not specified | minimum: 0.0 |
state_of_energy_start_wh |
number | Yes | Not specified | minimum: 0.0 |
unserved_load_w |
number | Yes | Not specified | minimum: 0.0 |
Issue Record
Issue Record¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
action_hint |
string or null | No | null |
anyOf branch 1: minLength: 1maxLength: 1000 |
code |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
issue_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
message |
string | Yes | Not specified | minLength: 1maxLength: 2000 |
severity |
Issue Severity | Yes | Not specified | — |
source_path |
string or null | No | null |
anyOf branch 1: minLength: 1maxLength: 512 |
statement_ids |
array of string | No | [] |
items: minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
Model Applicability Assessment
Model Applicability Assessment¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
active_limitation_ids |
array of string | No | [] |
items: minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
applicability_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
applied_default_policy_ids |
array of string | No | [] |
items: minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
authority_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
status |
Model Applicability Status | Yes | Not specified | — |
Model Applicability Status
Model Applicability Status¶
enum: ["applicable", "degraded", "unsupported"]
Panel Degradation Result
Panel Degradation Result¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
combined_retention |
number | Yes | Not specified | maximum: 1.0exclusiveMinimum: 0.0 |
technology |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
terms |
array of Eps Degradation Factor Term | Yes | Not specified | minItems: 1 |
uncertainty_case |
Eps Uncertainty Case | Yes | Not specified | — |
Resolved Array Section
Resolved Array Section¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
bol_power_density_w_per_m2 |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
component_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
continuous_current_a |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
eol_power_density_w_per_m2 |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
installed_area_m2 |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
mass_basis |
Array Mass Basis or null | No | null |
— |
mass_kg |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
realized_area_m2 |
number | Yes | Not specified | minimum: 0.0 |
section_count |
integer | Yes | Not specified | minimum: 1 |
voltage_max_v |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
voltage_min_v |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
Resolved Battery Pack
Resolved Battery Pack¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
component_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
continuous_charge_current_a |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
continuous_discharge_current_a |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
installed_bol_energy_wh |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
mass_kg |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
nominal_voltage_v |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
pack_count |
integer | Yes | Not specified | minimum: 1 |
peak_discharge_current_a |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
usable_eol_energy_wh |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
voltage_max_v |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
voltage_min_v |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
Resolved Eps Architecture
Resolved Eps Architecture¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
array |
Resolved Array Section | Yes | Not specified | — |
battery |
Resolved Battery Pack | Yes | Not specified | — |
bus_voltage_v |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
candidate_rejections |
array of Eps Candidate Rejection | No | [] |
— |
pcdu |
Resolved Pcdu | Yes | Not specified | — |
total_hardware_mass_kg |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
Resolved Pcdu
Resolved Pcdu¶
Unknown fields are rejected for this object.
| Field | Type | Required | Default | Constraints / meaning |
|---|---|---|---|---|
bus_voltage_v |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
component_id |
string | Yes | Not specified | minLength: 1maxLength: 128pattern: "^[a-z][a-z0-9]*(?:[._:-][a-z0-9]+)*$" |
continuous_current_a |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
continuous_power_w |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
mass_kg |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
peak_current_a |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
peak_power_w |
number | Yes | Not specified | exclusiveMinimum: 0.0 |
Schema integrity¶
Schema SHA-256: 4e0fb04eaa66b919d092bff7b484c40a776fe13fea5fe72495ef189db837719f.